A calibration calorimetry method to investigate the thermal characteristics of a cylindrical lithium-ion battery
L Sheng, Z Zhang, L Su, H Zhang, H Zhang, K Li… - … Journal of Thermal …, 2021 - Elsevier
… heat conduction calorimetry (IHC) and an accelerating rate … ratio of the radiant heat to the
convective heat transfer only has a … Thus, there only exists the convective heat transfer α c …
convective heat transfer only has a … Thus, there only exists the convective heat transfer α c …
Measurement of two-dimensional heat generation rate of pouch type lithium-ion battery using a multifunctional calorimeter
… cold plate, which increase the measurement error because of the low thermal conductivity. …
pouch type lithium-ion battery cell. The calorimeter uses heat flux sensors as the basis for the …
pouch type lithium-ion battery cell. The calorimeter uses heat flux sensors as the basis for the …
Design of Calorimeter and Heat Measurement of Lithium-ion Battery
Z Zheng - 2017 - search.proquest.com
… heat generation rate of the lithium-ion battery based on the instantaneous thermal power
which is measured by a heat flow sensor … , because the thermal conductivity of the heatsink is …
which is measured by a heat flow sensor … , because the thermal conductivity of the heatsink is …
Towards understanding heat generation characteristics of Li-ion batteries by calorimetry, impedance, and potentiometry studies
… is accompanied by heat generation and thermal runaway … are prime issues in Li-ion batteries,
the impending need for safety in … , we report heat generation in Li-ion batteries containing …
the impending need for safety in … , we report heat generation in Li-ion batteries containing …
High‐temperature battery calorimeter
LD Hansen, RH Hart, DM Chen… - Review of Scientific …, 1982 - pubs.aip.org
… limit of I mW, and an upper limit of heat flow of 50 W. The results of … as the thermal conductance
Ks between the two sensors also … AT across a path with a constant thermal conductivity. …
Ks between the two sensors also … AT across a path with a constant thermal conductivity. …
Design of a calorimeter for measurement of heat generation rate of lithium ion battery using thermoelectric device
… rate calorimetry (ARC) and isothermal heat conduction … used based on the heat transfer
model of the calorimeter, which … Current was measured by a high-resolution current sensor and …
model of the calorimeter, which … Current was measured by a high-resolution current sensor and …
Heat generation measurement and thermal management with phase change material based on heat flux for high specific energy power battery
H Wang, Y Wang, F Hu, W Shi, X Hu, H Li… - Applied Thermal …, 2021 - Elsevier
… apparatus like ARC(Accelerating Rate Calorimeter), and the heat flux sensor is … conductive
silver silicone grease was used to fill the space between the heat flux sensor and the battery …
silver silicone grease was used to fill the space between the heat flux sensor and the battery …
Thermal parameters determination of battery cells by local heat flux measurements
… thermal conductivity, of pouch-type cells is introduced. Application of local heat flux measurement
with a gradient heat flux sensor … anisotropy of thermal conductivity, electric conductivity, …
with a gradient heat flux sensor … anisotropy of thermal conductivity, electric conductivity, …
Experimental study on heat generation characteristics of lithium-ion batteries using a forced convection calorimetry method
R Cao, X Zhang, H Yang, C Wang - Applied Thermal Engineering, 2023 - Elsevier
… three methods of calorimetry according to the different means of heat transfer: conduction, …
[27] performed in situ measurements of heat generation rate by attaching a heat flux sensor …
[27] performed in situ measurements of heat generation rate by attaching a heat flux sensor …
[HTML][HTML] Novel methods for measuring the thermal diffusivity and the thermal conductivity of a lithium-ion battery
G White, A Hales, Y Patel, G Offer - Applied Thermal Engineering, 2022 - Elsevier
… internal heating to generate a response in the heat flux sensors. Both methods result in less
… Calorimetric methods were used to determine specific heat capacity, c p . The heater block …
… Calorimetric methods were used to determine specific heat capacity, c p . The heater block …